  Network Working Group Brian A. Anderson

  Request for Comments: 927 BBN

  December 1984

  TACACS User Identification TelnetOption

  Status of this Memo

  This RFCsuggests a proposed protocol for the ARPA-Internet community, and requests discussion and suggestions for improvements.

  Distribution of this memo is unlimited.

  Introduction

  The following is the description of a TELNET option designed to facilitate double login avoidance. It is intended primarily for TAC connections to target hosts on behalf of TAC users, but it can be used between any two consenting hosts. For example, all hosts at one site (e.g., BBN) can use this option to avoid double login when TELNETing to one another.

  1. Command name and code

  TUID 26

  2. Command Meanings

  IAC WILL TUID

  The sender (the TELNET user) proposes to authenticate the user and send the identifing UUID; or, the sender (the TELNET user) agrees to authenticate the user on whose behalf the connection is initiated.

  IAC WON'T TUID

  The sender (the TELNET user) refuses to authenticate the user on whose behalf the connection is initiated.

  IAC DO TUID

  The sender (the TELNET server) proposes that the recipient (the TELNET user) authenticate the user and send the identifing UUID; or, the sender (the TELNET server) agrees to accept the recipient's (the TELNET user's) authentication of the user identified by his UUID.

  RFC927December 1984

  TUID Telnet Option

  IAC DON'T TUID

  The sender (the TELNET server) refuses to accept the recipient's (the TELNET user) authentication of the user.

  IAC SB TUID IAC SE

  The sender (the TELNET user) sends the UUID of the user on whose behalf the connection is established to the host to which he is connected. The is a 32 bit binary number.

  3. Default

  WON'T TUID

  A TELNET user host (the initiatorof a TELNET connection) not implementing or using the TUID option will reply WON'T TUID to a DO TUID.

  DON'T TUID

  A TELNET server host (the recipient of a TELNET connection) not implementing or using the TUID option reply DON'T TUID to a WILL TUID.

  4. Motivation for the Option

  Under TACACS (the TAC AccessControl System) a user must be authenticated (give a correct name/password pair) to a TAC before he can connect to a host via the TAC. To avoid a second authentication by the target host, the TAC can pass along the user's proven identity (his UUID) to the that host. Hosts may accept the TAC's authentication of the user or not, at their option.

  The same option can be used between any pair of cooperating hosts for the purpose of double login avoidance.

  5. Description for the Option

  At the time that a host establishes a TELNET connection for a user to another host, if the latter supports the TUID option and wants to receive the user's UUID, it sends an IAC DO TUID to the the user's host. If the user's host supports the TUID option and wants to authenticate the user by sending the user's UUID, it responds IAC WILL TUID; otherwise it responds with IAC WON'T TUID. If both the user and server TELNETs agree, the user TELNET will then send the UUID to the server TELNET by sub-negotiation.

  RFC927December 1984

  TUID Telnet Option

  6. Examples

  There are two possible negotiations that result in the double login avoidance authentication of a user. Both the server and the user TELNET support the TUID option.

  S = Server, U = User

  Case 1:

  S-> IAC DO TUID

  U-> IAC WILL TUID

  U-> IAC SB TUID <32-bit UUID> IAC SE

  Case 2:

  U-> IAC WILL TUID

  S-> IAC DO TUID

  U-> IAC SB TUID <32-bit UUID> IAC SE

  There are also two possible negoitiations that do not result in the authentication of a user. In the first example the server supports TUID and the user TELNET doesn't. In the second example the user TELNET supports TUID but the server TELNET doesn't.

  S = Server, U = User

  Case 3:

  S-> IAC DO TUID

  U-> IAC WONT TUID

  Case 4:

  U-> IAC WILL TUID

  S-> IAC DONT TUID

  The TUID is transmitted with the subnegotiation command. For example, if the UUID had the value 1 the following string of octets would be transmitted:

  IAC SB TUID 0 0 0 1 IAC SE

  If the UUID had the value 255 the following string of octets would be transmitted:

  IAC SB TUID 0 0 0 IAC IAC IAC SE

  RFC927December 1984

  TUID Telnet Option

  If the UUID had the value of all ones the following string of octets would be transmitted:

  IAC SB TUID IAC IAC IAC IAC IAC IAC IAC IAC IAC SE